0A 2 Lines Fused, unplug before ser. 2 GxP Software is the latest, most secure software to achieve full FDA 21 CFR Part 11 and EudraLex Annex 11 compliance with streamlined workflows to ensure data integrity. Spectranet customer portalSpectraMax and VersaMax . 00 Add to cart Molecular Devices Microplate Reader Spectramax 384 340PC $ 6,295. Data were analyzed with GraphPad Prism. Manual for Molecular Devices versamax Laboratory Equipment (47 pages) Specifications: 1379/1379020-versamax. 파장 정확도 : < ±0. ces at one of the following telephone numbers: 408 747-1700 800 635-5577 U. Negative (phosphate buffered saline) (Gibco Waltham, MA, USA) and positive controls. Flexible calculations Data analysis features are available such as 21 different curve fit options, simplified cross-plate analysis and interpolation, and automatic calculations. The mouse hippocampal neuronal cell line HT22 is frequently used as an in vitro model to investigate the role of hippocampal cholinergic neurons in cognitive functions. DMEM medium supplemented with the same volume of kit reagent on an empty well was used as a blank. HL-60 cells were plated at a density of 3×105 cells/well on 6-well plates. 340‚ 850 nm. Plates values were acquired using a fluorescence microplate reader (570 nm; Versamax, Molecular Devices, San Jose, CA, United States). The system provides automation for up to 50 For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. 00 Sale price $ 0. ® SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. The Molecular Devices VersaMax ELISA Microplate Reader enables precise and accurate detection at. Wavelength Range. The plate was read at 570 nm after 5 min using Versamax (molecular devices, United States). It features a modular design that allows users to add or change detection cartridges according to their needs. The catalytic activity was calculated from the production rate of the hydrolyzed product, p-nitrophenol, by monitoring the absorption (405 nm) at room temperature. FAST AND ACCURATE METERTECH Microplate Reader $3,650. 03 billion doses of. S. 3 Methods 1. 0200-6117. 단일 튜브 디스펜싱에서 전체 96 및 384 well 플레이트세척까지 간소화된 Microplate 세척입니다. The signal was read on an ELISA plate reader (SpectraMax VersaMax, Molecular Devices, Sunnyvale, CA, USA). With its advanced features and user-friendly interface, the VersaMax is the perfect choice for a wide range of research. Cell viability was represented by percentage values compared to a control and then used to calculate the number of viable cells. Molecular Devices Versamax; Molecular Devices Vmax; Molecular Devices Fmax Fluorescence; Packard Fluorocount Fluorescence; Packard Spectracount; Tecan Spectrafluor Plus Multilabel; Perkin Elmer HTS-7000 Plus Multilabel; Skatron Skanstacker 300 Washer; Berthold LB96P Luminescence;Finally, cells were incubated with 1% SDS for 2 h at RT to release the dye from the cells, and the cell proliferation rate was assessed by quantification of the amount of dye released from the cells using a spectrophotometer (VersaMax, Molecular Devices) at the wavelength of 570 nm. All. SoftMax® Pro, the industry-leading microplate reader software, is included at no. Electrolyte leakage analysis was conducted using 8-day-old rice seedlings before and after cold stress treatments in different time points (0, 6, and 11 days) at 4°C. 0 OD Kinetic Read Time: 9 Second Minimum Interval Temperature Uniformity ±0. 5) containing 0. 专为科研检测平台量身打造的灵活且强大的小型微孔板读板机(酶标仪),具备终点法和动力学检测模式,标准配置6块滤光片,覆盖蛋白定量、细胞活力、农药残留、ELISA实验等. The plates were immediately measured at 405 nm for 6 min using a microtiter plate reader (VersaMax; Molecular Devices, Sunnyvale). The SpectraMax® absorbance spectrophotometers and plate readers provide the versatility and convenience for a wide range of assays such as ELISAs, nucleic acid and protein. Tristar 3 Multimode Microplate Reader. For more sample throughput, the system can be easily integrated into a full roboticThe VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. and California) Tunable Microplate Reader 100-240V ~ 4A 50-60 HZ T4. 4 Microplate Reader Software w WARRANTY. End-point IgG titers were established as the mean plus three standard deviations of. VersaMax,SpectraMax340PC384,190,Plus384MicroplateReadersUserGuide 2 0112-0126B ThisdocumentisprovidedtocustomerswhohavepurchasedMolecularDevicesequipment,software,Get the most out of SoftMax Pro. The VMax Microplate Reader is capable of reading up to two wavelengths at a time in the visible wavelength spectrum (400nm-750nm), with 4 filter choices included at time of purchase. VersaMax, SpectraMax 340PC384, 190, Plus 384 Microplate Readers User Guide Electromagnetic Compatibility Regulatory for Canada (ICES/NMB-001:2006) This ISM device complies with Canadian ICES-001. Cell. SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers. For the MTS assay, the CellTiter 96® AQ ueous One Solution Cell Proliferation Assay kit was used following the manufacturer's instruction. g. 1 mL. NORTH AMERICA. Our absorbance plate readers feature our PathCheck Sensor technology and industry-leading SoftMax® Pro Data Acquisition and Analysis Software. Molecular Devices公司的VersaMax读 板机为光栅型单色器读板机,拥有灵活检 测优势,无需加配额外的滤光片。 可调波长,无需滤光片,灵活 VersaMax读板机使用光栅单色器来选择 波长,其结果是选择确切的检测波长应用 于每个实验。波长范围从340nm到 With the VersaMax microplate reader, you will never have to buy another filter. 99 shipping. The plate was read at 570 nm using an ELISA reader (VERSAMax, Molecular Devices, VWR, Philadelphia, PA, USA). Whether bacteria were partially or completely inactivated by bone cement. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer. The absorbance was measured using a microplate reader (VERSAmax; Molecular Devices, San Jose, CA, USA) at an excitation wavelength of 530–560 nm. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. Description: The SpectraMax® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research. We would like to show you a description here but the site won’t allow us. 00. Florescence intensity was monitored on a Gemini XPS fluorescence microplate reader (Molecular Devices, Sunnyvale, CA, USA) set for 488 nm excitation and 520 nm emission. Regular price $ 0. 10. Color intensities were measured using microplate reader (Versamax, Molecular Devices, Inc. and California VERSAMAX Tunable Microplate Reader 100-240V - 4A 50-60 HZ T4. Spectrophotometers. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. S. Ann Arbor, MI, USA). ,, [28]. The final mixtures were allowed to react at 25 °C in the dark for 5 min. Optical Densitiy (OD) values were processed with a data reduction software (SoftMax Pro, Molecular Devices) using a 4-parameter logistic fitting algorithm to the standard curve, allowing the determination of antibody. DISCLAIMER Molecular Devices Corporation reserves the right to change its products and services at any time to incorporate technological developments. The blue formazan concentration formed in viable cells was measured at 570 nm using spectrophotometer (Versamax, Molecular Devices, São Paulo, Brazil). The narrowly focused light beam and optical design give you the same high performance with round bottom, flat bottom, or half area well plates. The index was evaluated at 48 and 72 hours normalized to that at 24 hours. Molecular Devices VersaMax Microplate Reader. SpectraMax ABS and ABS Plus Absorbance ELISA Microplate Readers. View the supported Window operating systems for the different versions of the SoftMax Pro software. VersaMax Absorbance Microplate Reader memungkinkan pemilihan hingga dua panjang gelombang sekaligus untuk deteksi absorbansi dalam. 0A Sunnyvale, CA Made in USA VersaMax price. DNA content in the supernatant (100 μl) was measured using a Quant-iT PicoGreen assay kit (Invitrogen) as per the manufacturer's instructions. 8). The lysozyme concentration of a sample was determined using a standard calibration curve made of a series of known lysozyme concentrations. 8. Used. Furthermore, VersaMax is reliable, which means more uptime and lower long-term cost of. OptiMax (Versamax non EXT) B0: Screenstation: all: Skanstacker: all: Skanwasher 300: all: Skanwasher 400: all: SpectraMax 190: N0:. reader (VersaMax, Molecular Devices, Sunnyvale, CA, USA) at 560 nm with background subtraction at 630 nm, based on which the corresponding cell viability was assessed. Molecular Devices Corporation SpectraTest ABS1 Validation Plate Warranty Molecular Devices Corporation warrants this product against defects in material or workmanship as follows: 1. The Organoid Innovation Center at Molecular Devices combines cutting-edge technologies with novel research methods to address key challenges of scaling complex 3D biological models. The quantity of nitrite in the samples was calculated using the concentration of sodium nitrite as a standard. The blue formazan concentration formed in viable cells was measured at 570 nm using spectrophotometer (Versamax, Molecular Devices, São Paulo, Brazil). Formerly known as MicroMax, Molecular Devices’ unique SpectraDrop™ Micro-Volume Microplate, offers the highest throughput solution for low volume measurement available onthe market today. 0. SpectraMax® i3 Multi-Mode Detection Platform. Concluding Remarks. It provides ready-to-run protocols, analysis algorithms, and 21 different curve fit options. This manual is subject to change without notice. +49-89-9620-2340 Fax +49-89-9620-2345 Japan Nihon Molecular Devices Tel. Select up to two wavelengths. The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. SoftMax® Pro Software is the leading solution for microplate reader control and data analysis, where our exclusive INSIDER members help to ensure it remains the most innovative research tool available. (VersaMax, Molecular Devices, USA). Cell viabilities were presented as the ratio of the absorbance of treated cells to the absorbance of control cells cultured with an extract of HDPE. 0%, 0-2. versamax, vmax, emax, uvmax, flexstation, softmax pro 5 gxp software, spectratest, molecular devices automation partners, gemini, lmax, assay protocols, data display, data analysis, assay. 3 Methods 1. We would like to show you a description here but the site won’t allow us. Molecular Devices, LLC. 00. The absorbance was measured at 570 nm and. Glossary of Terms. BMG Labtech - THERMOstar. The Molecular Devices VersaMax Microplate Reader is a high-performance laboratory instrument designed for fast and accurate measurements allowing for selection of up to two wavelengths at a time. Sterile AB medium and a mixture of Me 2 SO, methanol, and water (ratio v/v 1:1:8) served as negative controls. A solution of 10 millimolar L-DOPA (40 µL) was added to each sample and the blank. Select Start>Control panel>Device Manager. pdf file (03 Dec 2022) Manufacturer: Molecular Devices; Category of Device: Laboratory Equipment, Measuring Instruments; Document: versamax Operator's Manual, File Type: PDF;Search for used versamax. Offer Ends In: 5 Days 05: 02: 03. After waiting 15 minutes for colour development at room temperature, the reaction was stopped with 1 M H 2 SO 4, and optical density values were read using an ELISA reader (Versamax, Molecular Devices, LLC, USA) at a wavelength of 492 nm, and the results were given as OD values. This manual does not represent a commitment on the part of Molecular Devices Corporation. Tristar 3 Multimode Microplate Reader. ~ Bio-Tek ELx808 Microplate Reader $2,795. New and used Molecular Devices VersaMax's for sale on LabX. And the VERSAmax reader is robotics-compatible. 1% (w/v) naphtylethylenediamine-HCl], incubated at room temperature for 10 min, and then the absorbance at 540 nm was measured in a microplate reader (VersaMax™, Molecular. Assays were conducted in a 96-well microplate using ELISA microplate reader (VersaMax Molecular Devices, USA) and absorbance was measured at 475 nm. The reaction was stopped with 100 µL of H 2 SO 4 1 M and quantified in a spectrophotometer (VERSAmax, Molecular Devices, San Jose, CA, USA) at 450 nm. SpectraMax Plus384, 190, 340PC384, and VersaMax Installation Guide Author: Molecular Devices Subject: Installation Guide Keywords: SpectraMax Versa and others Detection Platform Created Date: 5/17/2023 2:14:27 PMThis version is compatible with the following instruments: SpectraMax® Mini Multi-Mode Microplate Reader (software version 7. Ann Arbor, MI, USA). and California) Tunable Microplate Reader 100-240V ~ 4A 50-60 HZ T4. Battery Backup Uninterruptible Power Supply (UPS) And Power Conditioner For MDS Sciex Molecular Devices VERSAmax Microplate Reader Quote Request. Molecular Devices also offers a mass spectrometry-based solution for food safety testingWe would like to show you a description here but the site won’t allow us. Monday to Friday 7am - 5pm Pacific Time. $199. Study conductThe amounts of chlorophyll a and chlorophyll b were measured at 664. Absorbance was read at 412 nm every minute for 10 min using a VersaMax (Molecular Devices, San Jose, CA) spectrophotometer. Molecular Devices Corporation reserves the right to change its products and services at any time to incorporate technological developments. The absorbance was assumed to be 100% for the control group. Cell survival rate of each sample was calculated as a percentage relative to cells incubated in D-MEM. ¨Molecular Devices is a life-science technology innovator Our integrated hardware and software solutions enable automated workflows—from start to finish—for any research application. The TBARS content was calculated according to the extinction coefficient as 155 mM −1 cm −1. The average OD 490 of 12 blank wells (Line 18) was then subtracted from the raw OD 490 obtained for each sample well. Direct cytotoxicity of HVJ-E and Laserphyrin®-HVJ-EThe MTT formazan crystals were dissolved by adding 50 μl DMSO to each well and the plates gently shaken until the MTT solution was dissolved. An aliquot of the samples dissolved in DMSO with 80 μL of phosphate buffer (pH 6. The absorbance of each well was measured at λ = 490 nm with a VersaMax (Molecular Devices, USA) microplate reader. The water extract afforded the greatest yield, and total phenolic and tannin. With optimized reagents, option to operate the. Molecular Devices公司的VersaMax读 板机为光栅型单色器读板机,拥有灵活检 测优势,无需加配额外的滤光片。 可调波长,无需滤光片,灵活 VersaMax读板机使用光栅单色器来选择 波长,其结果是选择确切的检测波长应用 于每个实验。波长范围从340nm到With the VersaMax microplate reader, you will never have to buy another filter. Taking into account the price differences between each seller and each country. 0 nm full width half maximum. 99 + $59. SpectraTest ABS1 Absorbance Validation Plate. 2 and 648. Softmax Pro 소프트웨어가 포함된 PC 워크스테이션 포함. We would like to show you a description here but the site won’t allow us. Although this manual has been prepared with every precaution to ensure accuracy, Molecular Devices SpectraMax and VersaMax Plate Readers OperatorÕs Manual Ñ 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. It also integrates with the powerful SoftMax Pro Software for. After three times washing, the reaction was colored by substrate 3,3’,5,5’-Tetramethylbenzidine (TMB) (T0440, Sigma), and stopped by 2 N HCl. We would like to show you a description here but the site won’t allow us. Narrow bandwidths deliver increased accuracy and enhanced peak. To update the driver. Molecular Devices memberdayakan para ilmuwan untuk memajukan diagnosis dini dan terapi yang lebih aman untuk pasien. Cell viability was represented by percentage values compared to a. The cells were treated with 15, 25, 30, and 45 nm-particles in order to compare the cytotoxicities of different sized nanoparticles on the treated cells. Each sample has a discrete sample beam and reference beam so that each well is measured directly. Activity was calculated as picomoles of substrate hydrolyzed per min. 8. Windows Home Editions are not supported. The limit of detection for each assay was 156. 3, Molecular Devices). The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. 0, 0. VERSA MAX-LUNABLE, MOLECULAR DEVICES, MICROPLATE R. The PathCheck Sensor is a revolutionary new awardwinning1 technology in SpectraMax® Instruments for measuring the fluid level in every well of a microplate 2–5. Cellular imaging was performed on a Confocal microscope (Olympus IX 81 + FV1000, Shanghai, China) using an excitation wavelength of 380 nm. DISCLAIMER Molecular Devices Corporation reserves the right to change its products and services at any time to incorporate technological developments. The catalytic activity was calculated from the production rate of the hydrolyzed product, p-nitrophenol, by monitoring the absorption (405 nm) at room temperature. to 11. Add to Cart. ImmunohistochemistryAfter 1 h incubation at 37 °C, the color intensity was measured at 562 nm by a microplate reader (model VERSAmax; Molecular Devices, San Jose, CA, USA). 9. Molecular aspects of color variation in luciferase emission have been the subject of numerous studies: various mechanisms have been proposed [6] and multicolor reporter proteins have been created and applied in cell-based. That's why our team is at your disposal the majority of time. Table of Contents. One microgram of RNA was. After 4 h of incubation at 37 °C, culture medium was discarded and dimethyl sulfoxide (150 μL/well; Sigma) was inoculated to dissolve the precipitated formazan produced in viable cells. E. 72 MB. reader (VersaMax, Molecular devices, San Jose, CA, USA). All the experiments were conducted at. SoftMax® Pro, the industry-leading microplate reader software, is included at no additional charge. Briefly, at 3 h before each of the desired time points, 10 µl of the MTS reagent. p-nitrophenol (Sigma) with diluted concentrations ranging from 0 to 0. 온도 균일성 ±0. 17. 00 USD. 00 Read more Molecular Devices Tunable Microplate Reader VersaMaxMicroplate reader with 450 nm filter, such as VersaMax (Molecular Devices, Sunnyvale, CA). Microplate Readers Biotek Synergy H1 Hybrid Microplate Reader. from Molecular Devices Corporation. Table of Contents. The Molecular Devices VersaMax Absorbance Microplate Reader enables both precise and accurate detection at wavelengths in the visible spectrum. 00 USD. Select Update Driver. , Sunnyvale, CA). Dual monochromatic, three modes detection, UV Vis Abs, Fluor, and Lum, cuvette. The number of cells that migrated to the bottom was determined by measuring the optical density at 590 nm, using a microplate reader (VersaMax; Molecular Devices). Read-out was performed within 30 minutes with a microtiter plate reader at 450 nm (Versamax, Molecular Devices). Resveratrol (1 µ M) was expected to produce a sufficient effect on ER-stress and ROS production and was applied for subsequent analysis; a dose-dependent effect was also investigated by using 1 and. The SpectraTest® ABS1 Absorbance. Cell viability was quantified by microplate reader (VersaMax, Molecular Devices, San Jose, CA, USA) at 570 nm. 1. 8 in. Microplate Reader Capability > UV - Vis Absorbance. SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. , St. Values are presented as the mean ?standard deviation (SD). 9000-0756. 9000-0756. The objectives of this study were to determine phytochemical compositions, chemiluminescence antioxidant activities, and neuroprotective effects on PC12 cells for water, methanol, and 95% ethanol extracts of the air-dried fruit of <i>Terminalia chebula</i> Retzius. The samples were incubated with FBS, and the optical density of particles was determined with a microplate reader (VERSAmax, Molecular Devices, Sunnyvale, CA) by measuring the absorbance at 560 nm for 2 h. SoftMax® Pro, the industry-leading microplate reader software, is included at no additional charge. Cell viability was calculated using the following formula, where OD t is the absorbance of the treated cells and OD c is the absorbance of control cells: Cell viability = O D t / O D c. The reaction in the wells was stopped by the addition of 50 μl of 1 M sulfuric acid, which turned the wells yellow. The senescence-associated β -galactosidase activity (SA- β -gal) was measured using β -galactosidase Assay Kit following manufacturer's protocol. The absorbance was detected at 570 nm with a Microplate Reader (VersaMax, Molecular Devices, Sunnyvale, CA). treatments were then examined atλ=570 nm using VersaMax eliSa reader (Molecular devices, llc. The SpectraTest® ABS1 Absorbance Validation. SoftMax® Pro Software Validation Package provides the most comprehensive documentation and tools available to validate GxP administrator features, software. 747. Although this manual has been prepared with every precaution to ensure accuracy, Molecular DevicesThe amount of extracted crystal violet was measured at 595 nm using a microplate reader (VersaMax, Molecular Devices Co. For wells that were not exposed to dehydration (positive control), all the cells (100%) survived for the 60-min test. VersaMax ELISA Microplate Reader from Molecular Devices, LLC Description Enables precise and accurate detection at wavelengths in the visible spectrum without the use of. Thus, the molecular mechanism promoting hepatic lipid accumulation in obesity is of biomedical and public health interest. Search for used versamax. SpectraMax ABS and ABS Plus Absorbance ELISA Microplate Readers. SpectraMax Plus384 SpectraMax 190 SpectraMax 340PC384 VersaMax Microplate Spectrophotometer Operator s Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. The robot-compatible VersaMax Reader is cost-effective—users never have to buy filters. This reliable model allows for accurate wavelength detection in visible spectrum without the need for filters. Microplate Readers Molecular Devices Spectramax iD3 Microplate Reader. Additionally, the VersaMax Microplate Reader can be seamlessly integrated with the StakMax® Microlate Handling System through the SoftMax Pro Software. Preconfigured method protocols specifically written for the Pyrochrome Assay and other ACC assays are available for SoftMax Pro Software and take. 1700 +1 800. The eight-channel system- consisting of 8 sample beams and 8 reference beams delivers both. Molecular Devices Beijing Tel. 0 OD. 00 Regular price. Get pricing and purchase lab equipment and instrumentation today. S. Home - University of Victoriaimported directly into Excel (Microsoft, Redmond, WA) from the ELISA microplate reader (VersaMax; Molecular Devices, Sunnyvale, CA, USA). New and used Molecular Devices VersaMax's for sale on LabX. [Google. measured over 60min using a microplate reader (VersaMax, Molecular Devices, Sunnyvale, CA) at a wavelength of 405nm. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection. The VersaMax reader uses the best plate for your assay. With a wavelength range from 340 to 850 nm, it is the equivalent to having 510 free filters. GABA concentrations in samples were calculated from calibration curves using the standard solutions. The absorbance of the mixture was measured with a microplate reader (VERSAmax™, Molecular device, Sunnyvale, USA) at wavelength of 498 nm until absorbance was saturated. 0 software (GraphPad). absorbance readers. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate. ChE activity was normalized by protein concentration as determined by a Coomassie. Acetylcholinesterase activity was calculated as the rate of change of absorbance per minute during the linear portion of the reaction and normalized by protein concentration as determined by a Coomassie. +86-21-6887-8820 fax +86-21-6887-8890 Germany Molecular Devices GmbH Tel. With its advanced features and user-friendly interface, the VersaMax is the perfect choice for a wide range of research. printed in u. All parts of the SpectraTest ABS1 Validation Plate are warranted for a period of ninety (90) days from the original date of delivery. 00 USD. The plate was read at 570 nm using an ELISA reader (VERSAMax, Molecular Devices, VWR, Philadelphia, PA, USA). In general terms, plasma was added to a 96-well plate containing the targeted antisera, after rigorous washing steps and conjugation with a secondary detection antisera, and the resultant colorimetric reaction was read by scanning spectrophotometry (VersaMax, Molecular Devices, Sunnyvale, CA). Read-out was performed within 30 minutes with a microtiter plate reader at 450 nm (Versamax, Molecular Devices). However, whether these cells exhibit the serotonergic neuronal phenotype observed in mature hippocampal neurons. Cyanobacterial strains that did not lyse until the 12th day were defined as insusceptible. Louis, USA) was used to. The absorbance was read at 570 nm using a spectrophotometer (VersaMax, Molecular Devices, San Jose, CA, USA). 00 Sale price $ 0. ) for the next 36 h and provided a time-proliferation curve as a test result for each well of the microplate. 5°C @ 37°C Well-to. $199. For more advanced automation needs, Molecular Devices interacts with all of the major lab automation providers, and is one of their leading choices. MOLECULAR DEVICES VersaMax is a customizable lab equipment capable of performing multiple types of research-grade tests and experiments at once, with enhanced safety protocols and adjustable column and sample-loading system for efficient sample preparation and increased throughput. Microplate Readers Thermo Fluoroskan Ascent FL Fluorescence Microplate Reader. Supplier: Molecular Devices. This technical note is designed to provide information . 4 Microplate Reader Software w WARRANTY. Coat plate with 100 μL each of appropriately diluted standards (Table 1),. The optical density was measured at a wavelength of 450 nm using VersaMax (Molecular Devices, Seoul, South Korea). SpectraMax Plus384, 190, 340PC384, and VersaMax User Guide Molecular Devices User Guide SpectraMax. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. TECHNICAL NOTE. Statistical Analysis. The BMDM cells were plated into a 6-well culture plate at a density of 2. Filterless Absorbance Microplate Readers provides fast & consistent results with steady temperature enabling a wide range of assays - ELISA reader, microbial. g. Molecular Devices VersaMax Tunable Microplate Reader. Reboot the computer. However, whether these cells exhibit the serotonergic neuronal phenotype observed in mature hippocampal neurons. Integrate any SpectraMax Multi-Mode Reader with the StakMax Microplate Handling System from Molecular Devices. Select the Driver tab. Next, 100 μL of a reagent was added to an equal volume of cell culture medium present in each well. VersaMax,SpectraMax340PC384,190,Plus384MicroplateReadersUserGuide 4 0112-0126B SafetyInformation InformationaboutthesafeuseoftheinstrumentfromMolecularDevices®includesan Get the most out of SoftMax Pro. . +49-89/96-05-88-0 fax +49-89/9-62-02-34-5 Japan Nihon Molecular Devices Osaka Tel. The Molecular Devices VersaMax Microplate Reader is a high-performance laboratory instrument designed for fast and accurate measurements of absorbance, fluorescence, and luminescence from 6 to 384-well microplates. After that, absornace were measured at 520 nm using using a microplate reader spectrophotometer VERSAmax (Molecular Devices). The instrument reads any standard cuvette, microcuvette, test tube or 96- and 384-well standard or UV transparent microplate over a full 190 to 1000. ® The VersaMax™ Microplate Reader from Molecular Devices bridges the gap between the affordability of filter-based readers and the flexibility of monochromator-based systems. Page 2 Molecular Devices Corporation warrants this product against defects in material or workmanship as follows: 1) All. The assays were conducted in a 96-well microplate using an ELISA microplate reader (VersaMax Molecular Devices, United States) to measure absorbance at 475 nm. Table 1. Tunable, filterless flexibility The. Bovine serum albumin was used as a reference. molecular devices | 1311 orleans drive | sunnyvale, cA 94089 usA | email: info@moldev. To evaluate the reliability of the assay, SkinEthic TM RHE (1% Triton X-100) was used. Manufacturer: Molecular Devices; Includes PC Workstation w/ Softmax Pro Software Wavelength Range (nm): 340–850 Wavelength Accuracy: < ±0. 4 (Molecular Devices cat. For more information, please visit us at 160 µL of sample solutions/positive control (ascorbic acid) were mixed with 40 µL of DPPH solution and incubated at room temperature for 30 min. MOLECULAR DEVICES VMAX KINETIC MICROPLATE READER. Microplate readers from Molecular Devices are designed to provide consistent performance over a long period of time. No accessories are needed and SoftMax® Pro Software. Molecular Devices Corporation. Then, the absorbance at a wavelength of 450 nm was measured using an absorption microplate reader (VersaMax, Molecular Devices, USA) to evaluate the cell survival rate. Youmustensurethatthemeniscusiscomfortablyabove thelightbeaminstandardcuvettesandthatthesamplechamberinamicrocuvetteis Microplate Reader Capability > UV - Vis Absorbance. Find Fanuc, Molecular Devices, Eagle, and GE for sale on Machinio. repurposing of drug molecules already approved, or in clinical trials, for other viruses. Culture medium was removed, and lysis buffer (10 ml) was pipetted into each well. Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. The rate of cell viability was calculated using the following formula:The conversion of NADP+ to NADPH was measured as absorbance (340 nm) on a microplate reader (VersaMax, Molecular Devices Co. The optical density (OD) was measured at 570 nm (with a reference at 690 nm) by UV-visible spectrophotometer (VersaMax, Molecular Devices, CA, USA) in triplicates. 2. Turn the reader on and secure the USB cable. S. VersaMax,SpectraMax340PC384,190,Plus384MicroplateReadersUserGuide 11 0112-0126B Theguidelinesforcuvetteuseintheinstrumentarethesameasthosethatapplytoany high-qualityspectrophotometer. 23,225, Thermo Fisher Scientific). The sections were stained with hematoxylin and eosin (H&E) and. Download PDF versions of the SpectraMax Microplate Reader User Guides. 1 N NaOH (50 μl) followed by absorbance measurement at 405 nm with a plate reader (VersaMax, Molecular Devices, Sunnyvale, CA). 8), 40 μL of tyrosinase, and 40 μL of L-DOPA were put in each well. Select Update Driver. Quantitative real-time polymerase chain reaction For quantitative real-time polymerase chain reaction (qRT-PCR) analysis, total cellular RNA was extracted from ten zebrafish larvae. SoftMax Pro 7. Conventions Used in this Manual. 003 OD ±1. Absorbance was read at 412 nm every minute for 10 min using a VersaMax (Molecular Devices, San Jose, CA) spectrophotometer. The growth inhibitory rate (GIR) of treated cells was calculated by Equation 1. Cells were treated with 150 μl of DMSO and absorbance was quantified in 540 nm using the microplate spectrophotometer system (VersaMax, Molecular Devices, Sunnyvale, CA, USA). Tunable, filterless flexibility The VersaMax reader uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. 00 Read more Molecular Devices Tunable Microplate Reader VersaMaxMicroplate reader with 450 nm filter, such as VersaMax (Molecular Devices, Sunnyvale, CA). Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. The Molecular Devices VersaMax Tunable Microplate Reader for 96-well format uses a grating monochromator to select the wavelength, so the exact wavelength needed can be selected for every assay. Versamax Microplate Reader dibangun di sekitar monokromator kisi. We would like to show you a description here but the site won’t allow us. Spectrofluorometer (e. For the name of the nearest authorized Molecular Devices Corporation service facility, please contact Molecular Devices at one of the following telephone numbers: (408) 747-1700 (800) 635-5577 (U. The. Cells were treated with 150 μl of dimethylsulfoxide (DMSO) and absorbance was quantified at 540 nm using the microplate spectrophotometer system (VersaMax, Molecular Devices, Sunnyvale, CA, USA). The. 0. 4. ® Standalone instrument with touchscreen and built-in sample ports for small volumes and cuvettes. Using a Spectradrop Micro-Volume Microplate (VersaMax, Molecular Devices, CA, USA), RNA was quantified, and 1 μg of total RNA was treated with DNase I (Thermo Scientific, Waltham, MA, USA) before. , Sunnyvale, CA, USA). While the situation is vastly improving with numerous vaccine rollouts and over 6. After incubation for 1 h, the medium was transferred to 96-well plates (SPL Life Sciences) in triplication and absorbance was measured by using the ELISA microplate reader (VersaMax, Molecular Devices, USA) at 490 nm. The increase of absorbance at 405. Coat plate with 100 μL each of appropriately diluted standards (Table 1),. VersaMax ELISA Microplate Reader. We would like to show you a description here but the site won’t allow us. Our multi-mode plate readers provide great flexibility and include absorbance, fluorescence and luminescence with configurable options for fluorescence polarization (FP), time. Model: VERSAmax Tunable Microplate Reader. 5×10 3 cells were seeded in 96-well plates, treated with indicated inhibitors for 48 or 72 hours, analyzed 16 hours after BrdU addition, and absorbance measured at 450nm using a spectrophotometer plate reader (VersaMax, Molecular. While the cell covers about. Spectranet customer portalThe absorbance was recorded at 532 nm using a microplate reader (VERSAmax, Molecular Devices, Sunnyvale, USA). Oil red O staining. Related products. The Molecular Devices SpectraMax XPS has an optical design that is the only multi-channel system that truly mimics a dual-beam spectrophotometer. $1,195. We would like to show you a description here but the site won’t allow us. VersaMax,SpectraMax340PC384,190,Plus384MicroplateReadersUserGuide 11 0112-0126B Theguidelinesforcuvetteuseintheinstrumentarethesameasthosethatapplytoany high. The absorbance of reaction mixtures was read at 475 nm using a microplate reader (VERSAMax, Molecular Devices) to determine the quantity of dopachrome produced. Used. For determination of the optimal temperature, EfmTDC was incubated in 100 mM sodium acetate buffer (pH 5. After treatment with GA3The absorbance was measured with a microplate reader (VERSAmax, Molecular devices, San Jose, CA, USA) at 570 nm according to the manufacturer’s instructions. Technical Specifications. Invasion assayCells were seeded into the top chamber of a 96-well matrigel-coated plate with 8-m-pore polyethylene terephthalate membrane inserts (Corning). Our specialization servicing microplate instrumentation and our focus on a narrow range of product lines allows us to provide the highest standards of service and ensure. Absorbance was measured with a microplate reader (VERSAmax Molecular Devices Corporation, Sunnyvale, CA, USA) at 570 nm to assess cell viability. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part #0112-0140 Rev. Approximately.